  "metadata": {
    "schemaVersion": 1,
    "reviewedDate": "2026-10-20",
    "language": "cs",
    "device": "Victron SmartSolar MPPT 100/20",
    "scope": "Číselník rodiny BlueSolar/SmartSolar MPPT doplněný přesným manuálem 75/10 až 100/20; pouze čtení.",
    "stateCount": 12,
    "errorCount": 43,
    "countsIncludeUnavailable": true,
    "mpptHexStates": [
      0,
      2,
      3,
      4,
      5,
      6,
      7,
      245,
      247,
      250,
      252,
      255
    ],
    "mpptHexErrors": [
      0,
      2,
      3,
      4,
      5,
      6,
      7,
      8,
      14,
      17,
      18,
      19,
      20,
      21,
      22,
      23,
      26,
      27,
      28,
      29,
      33,
      34,
      38,
      39,
      66,
      67,
      68,
      116,
      117,
      119
    ],
    "modelManualErrors": [
      1,
      2,
      17,
      18,
      20,
      21,
      26,
      28,
      33,
      38,
      39,
      40,
      80,
      81,
      82,
      83,
      84,
      85,
      86,
      87,
      88,
      116,
      117,
      119
    ],
    "textProtocolAdditionalErrors": [
      65
    ],
    "unavailableCode": 255,
    "knownMeaning": "Kód má doložený význam v tomto číselníku. Neprokazuje podporu všech režimů na konkrétním modelu ani aktuálnost měření.",
    "severityMeaning": "Závažnost je klasifikace tohoto webu. Kódy 65 a 66 jsou v dokumentaci Victron vedené jako Information a zde jako warning.",
    "notes": [
      "Kódy stavu a chyby jsou dvě samostatná pole. Stejné číslo může mít v každém poli jiný význam.",
      "0 v chybovém poli znamená bez chyby; 255 znamená nedostupný údaj. Chybějící údaj zůstává null.",
      "Nezařazený kód zůstává neznámý. Číselník nevydává nedoložené hodnoty za rezervované ani za bezchybný stav.",
      "Některé režimy, čidla a ochrany závisejí na modelu, jeho možnostech a firmwaru.",
      "Kód chyby 19 se od firmwaru 1.15 nehlásí. Ochrana 20 byla z novějšího solárního firmwaru odstraněna. Kód 34 byl odstraněn ve verzi 1.29.",
      "Kód 21 mohl být na starém firmwaru přechodný při startu nebo vypínání; od 1.16 se takové nepřetrvávající upozornění nehlásí. Web přijatou aktivní chybu neskrývá.",
      "Automatická ekvalizace: firmware do 1.39 včetně ji může hlásit stavem 4; od 1.42 používá stav 247. Přesná interpretace starších verzí vyžaduje další údaje.",
      "Kód 88 je uveden v rozsahu 80–88 v modelovém manuálu, sekce 8.12.12. Obecný webový seznam uvádí 80–87; pro 88 nepřidáváme podrobnější příčinu.",
      "V obecném webovém seznamu jsou i chyby jiných produktů. Položky bez opory v MPPT HEX, modelovém manuálu nebo MPPT ERR tabulce nebyly převzaty.",
      "Popisy nejsou postupy oprav. Web nemění nastavení, neprovádí reset a neurčuje stav nabití baterie z fáze nabíjení."
    ],
    "sources": [
      {
        "id": "mppt-hex-rev18",
        "title": "VE.Direct Protocol — BlueSolar and SmartSolar MPPT chargers, Rev. 18",
        "url": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf",
        "sections": "Device state values, s. 8; Charger error code values, s. 13; capabilities, s. 7."
      },
      {
        "id": "mppt-100-20-manual",
        "title": "SmartSolar MPPT 75/10 až 100/20 — Troubleshooting",
        "url": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html",
        "sections": "8.12. Error code overview; 8.12.12. Error 80 to 88."
      },
      {
        "id": "mppt-error-codes",
        "title": "Victron Energy — MPPT Solar Charger Error Codes",
        "url": "https://www.victronenergy.com/live/mppt-error-codes",
        "sections": "Aktuální vysvětlení kódů. Seznam zahrnuje i jiné produktové řady."
      },
      {
        "id": "ve-direct-3-34",
        "title": "VE.Direct Protocol 3.34",
        "url": "https://www.victronenergy.com/upload/documents/VE.Direct-Protocol-3.34.pdf",
        "sections": "ERR, s. 15; informační kódy 65 a 66 a poznámky ke staršímu firmwaru."
      },
      {
        "id": "ble-advertising-2022-12-14",
        "title": "Victron BLE advertising extra manufacturer data, 2022-12-14",
        "url": "https://communityarchive.victronenergy.com/storage/attachments/extra-manufacturer-data-2022-12-14.pdf",
        "sections": "Solar Charger record 0x01, s. 3: device state a charger error, 0xFF = nedostupné."
      }
    ]
  },
  "states": {
    "0": {
      "code": 0,
      "label": "Nenabíjí",
      "known": true,
      "severity": "normal",
      "description": "Regulátor právě nenabíjí. Samotný kód neurčuje důvod ani stav výstupu LOAD.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "2": {
      "code": 2,
      "label": "Porucha",
      "known": true,
      "severity": "error",
      "description": "Regulátor hlásí poruchový stav. Podrobnost určuje samostatný kód chyby.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "3": {
      "code": 3,
      "label": "Hlavní nabíjení · Bulk",
      "known": true,
      "severity": "normal",
      "description": "Fáze nabíjení podle nastaveného nabíjecího proudu.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "4": {
      "code": 4,
      "label": "Absorpce",
      "known": true,
      "severity": "normal",
      "description": "Fáze řízená nastaveným absorpčním napětím. Starší firmware zde může hlásit také automatickou ekvalizaci.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "5": {
      "code": 5,
      "label": "Udržování · Float",
      "known": true,
      "severity": "normal",
      "description": "Fáze řízená nastaveným udržovacím napětím. Neurčuje přesné procento nabití baterie.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "6": {
      "code": 6,
      "label": "Skladovací režim",
      "known": true,
      "severity": "normal",
      "description": "Fáze řízená skladovacím napětím, pokud ji daný model a firmware podporují.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "7": {
      "code": 7,
      "label": "Ruční ekvalizace",
      "known": true,
      "severity": "info",
      "description": "Probíhá ručně zahájená fáze řízená ekvalizačním napětím.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "245": {
      "code": 245,
      "label": "Spouštění",
      "known": true,
      "severity": "info",
      "description": "Regulátor se připravuje ke spuštění.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "247": {
      "code": 247,
      "label": "Automatická ekvalizace",
      "known": true,
      "severity": "info",
      "description": "Probíhá automatická fáze řízená ekvalizačním napětím.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "250": {
      "code": 250,
      "label": "Probíhá aktualizace",
      "known": true,
      "severity": "info",
      "description": "Regulátor je během aktualizace dočasně nedostupný.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "252": {
      "code": 252,
      "label": "Externí řízení",
      "known": true,
      "severity": "info",
      "description": "Nabíjení řídí externě zadaná hodnota napětí.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=8"
    },
    "255": {
      "code": 255,
      "label": "Stav nedostupný",
      "known": false,
      "severity": "unknown",
      "description": "Hodnota 255 (0xFF) znamená, že údaj o stavu není k dispozici.",
      "helpUrl": "https://communityarchive.victronenergy.com/storage/attachments/extra-manufacturer-data-2022-12-14.pdf#page=3"
    }
  },
  "errors": {
    "0": {
      "code": 0,
      "label": "Bez chyby",
      "known": true,
      "severity": "normal",
      "description": "Regulátor v tomto údaji nehlásí chybu.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=13"
    },
    "1": {
      "code": 1,
      "label": "Vysoká teplota baterie",
      "known": true,
      "severity": "error",
      "description": "Nabíjení bylo zastaveno kvůli teplotě baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-18ce5124-d297-8e1b-f727-2d7c8dc19e8a"
    },
    "2": {
      "code": 2,
      "label": "Vysoké napětí baterie",
      "known": true,
      "severity": "error",
      "description": "Napětí baterie překročilo povolenou hodnotu.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-ab062f94-b8b4-3b6b-6d99-f6f3ce0508ee"
    },
    "3": {
      "code": 3,
      "label": "Chyba teplotního čidla",
      "known": true,
      "severity": "error",
      "description": "Chyba měření teploty baterie vzdáleným čidlem.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_3_err_4_-_remote_temperature_sensor_failure"
    },
    "4": {
      "code": 4,
      "label": "Chyba teplotního čidla",
      "known": true,
      "severity": "error",
      "description": "Chyba měření teploty baterie vzdáleným čidlem.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_3_err_4_-_remote_temperature_sensor_failure"
    },
    "5": {
      "code": 5,
      "label": "Ztráta teplotního čidla",
      "known": true,
      "severity": "error",
      "description": "Spojení se vzdáleným teplotním čidlem bylo ztraceno.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_5_-_remote_temperature_sensor_failure_connection_lost"
    },
    "6": {
      "code": 6,
      "label": "Chyba měření napětí baterie",
      "known": true,
      "severity": "error",
      "description": "Chyba vzdáleného snímání napětí baterie.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_6_err_7_-_remote_battery_voltage_sense_failure"
    },
    "7": {
      "code": 7,
      "label": "Chyba měření napětí baterie",
      "known": true,
      "severity": "error",
      "description": "Chyba vzdáleného snímání napětí baterie.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_6_err_7_-_remote_battery_voltage_sense_failure"
    },
    "8": {
      "code": 8,
      "label": "Ztráta měření napětí baterie",
      "known": true,
      "severity": "error",
      "description": "Spojení pro vzdálené snímání napětí baterie bylo ztraceno.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_8_-_remote_battery_voltage_sense_failure_connection_lost"
    },
    "14": {
      "code": 14,
      "label": "Nízká teplota baterie",
      "known": true,
      "severity": "error",
      "description": "Ochrana nedovoluje nabíjení při nízké teplotě baterie.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_14_-_battery_low_temperature"
    },
    "17": {
      "code": 17,
      "label": "Přehřátí regulátoru",
      "known": true,
      "severity": "error",
      "description": "Regulátor se přehřál i po omezení výstupního proudu.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-d8ad120b-0938-f3af-8029-712b3948fc81"
    },
    "18": {
      "code": 18,
      "label": "Nadproud regulátoru",
      "known": true,
      "severity": "error",
      "description": "Regulátor zaznamenal nadměrný proud na bateriové straně.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-2b0da2b1-814f-4636-ad04-b991f15a2bbd"
    },
    "19": {
      "code": 19,
      "label": "Obrácený proud nabíječky",
      "known": true,
      "severity": "error",
      "description": "Historický kód opačného směru proudu; od firmwaru 1.15 se nehlásí.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/VE.Direct-Protocol-3.34.pdf#page=15"
    },
    "20": {
      "code": 20,
      "label": "Překročená doba Bulk",
      "known": true,
      "severity": "error",
      "description": "Historická ochrana maximální doby hlavního nabíjení; z novějšího firmwaru MPPT byla odstraněna.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-a511a64c-7128-587f-a3aa-9ce51457db33"
    },
    "21": {
      "code": 21,
      "label": "Chyba proudového čidla",
      "known": true,
      "severity": "error",
      "description": "Měření proudu je mimo očekávaný rozsah.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_21_-_current_sensor_issue"
    },
    "22": {
      "code": 22,
      "label": "Chyba vnitřního teplotního čidla",
      "known": true,
      "severity": "error",
      "description": "Vnitřní měření teploty je mimo očekávaný rozsah.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_22_err_23_-_internal_temperature_sensor_failure"
    },
    "23": {
      "code": 23,
      "label": "Chyba vnitřního teplotního čidla",
      "known": true,
      "severity": "error",
      "description": "Vnitřní měření teploty je mimo očekávaný rozsah.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_22_err_23_-_internal_temperature_sensor_failure"
    },
    "26": {
      "code": 26,
      "label": "Přehřáté svorky",
      "known": true,
      "severity": "error",
      "description": "Regulátor hlásí přehřátí výkonových svorek.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-86faf2c9-6422-1db0-9493-7b71e8712929"
    },
    "27": {
      "code": 27,
      "label": "Zkrat na výstupu nabíječky",
      "known": true,
      "severity": "error",
      "description": "Ochrana hlásí nadproud na bateriové straně.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_27_-_charger_short_circuit"
    },
    "28": {
      "code": 28,
      "label": "Porucha výkonového stupně",
      "known": true,
      "severity": "error",
      "description": "Hlásí poruchu výkonového měniče; podrobnost závisí na provedení regulátoru.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-ac1ab531-8e25-21ab-14e6-f5224a34c502"
    },
    "29": {
      "code": 29,
      "label": "Ochrana proti přebití",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana baterie před nadměrným nabíjecím napětím.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_29_-_over-charge_protection"
    },
    "33": {
      "code": 33,
      "label": "Vysoké napětí panelů",
      "known": true,
      "severity": "error",
      "description": "Napětí na FV vstupu překročilo povolenou hodnotu.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-d04c0e62-4f86-42e4-3890-f2210b84ac5d"
    },
    "34": {
      "code": 34,
      "label": "Nadproud z panelů",
      "known": true,
      "severity": "error",
      "description": "Historický kód nadměrného vstupního proudu; z firmwaru MPPT byl odstraněn ve verzi 1.29.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=13"
    },
    "38": {
      "code": 38,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "FV vstup byl ochranně vypnut kvůli nadměrnému napětí baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-56348770-efd6-abd8-86ce-09cc28d3f2cf"
    },
    "39": {
      "code": 39,
      "label": "Proud při vypnutém měniči",
      "known": true,
      "severity": "error",
      "description": "FV vstup byl ochranně vypnut; proud protékal i při vypnutém měniči.",
      "helpUrl": "https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf#page=13"
    },
    "40": {
      "code": 40,
      "label": "Selhání vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Regulátor nedokázal vypnout FV vstup a aktivoval ochranu baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-e4d9a796-5d21-811e-c76a-f4f3fd27195d"
    },
    "65": {
      "code": 65,
      "label": "Upozornění na komunikaci",
      "known": true,
      "severity": "warning",
      "description": "Ztratilo se spojení s jedním ze souběžně pracujících regulátorů.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#information_65_-_communication_warning"
    },
    "66": {
      "code": 66,
      "label": "Neslučitelná konfigurace zařízení",
      "known": true,
      "severity": "warning",
      "description": "Zařízení pro společné nabíjení mají neslučitelné nastavení nebo řízení.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#information_66_-_incompatible_device"
    },
    "67": {
      "code": 67,
      "label": "Ztráta spojení s BMS",
      "known": true,
      "severity": "error",
      "description": "Regulátor očekává řízení od BMS, ale nepřijímá jeho zprávy.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_67_-_bms_connection_lost"
    },
    "68": {
      "code": 68,
      "label": "Konflikt síťového řízení",
      "known": true,
      "severity": "error",
      "description": "Regulátor dostává konfliktní údaje ze zdrojů se stejnou prioritou.",
      "helpUrl": "https://www.victronenergy.com/live/mppt-error-codes#err_68_-_network_misconfigured"
    },
    "80": {
      "code": 80,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "81": {
      "code": 81,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "82": {
      "code": 82,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "83": {
      "code": 83,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "84": {
      "code": 84,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "85": {
      "code": 85,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "86": {
      "code": 86,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "87": {
      "code": 87,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "88": {
      "code": 88,
      "label": "Ochranné vypnutí FV vstupu",
      "known": true,
      "severity": "error",
      "description": "Aktivovala se ochrana FV vstupu proti přebíjení baterie.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9c0e1522-4368-bc01-934e-962a95a88082"
    },
    "116": {
      "code": 116,
      "label": "Ztráta kalibračních dat",
      "known": true,
      "severity": "error",
      "description": "Aktivní chyba označuje problém kalibračních dat. Samotný záznam v historii není důkazem současné poruchy.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-b43693be-6b13-166e-2f4f-0b1c5714a342"
    },
    "117": {
      "code": 117,
      "label": "Nekompatibilní firmware",
      "known": true,
      "severity": "error",
      "description": "Firmware je nekompatibilní nebo jeho aktualizace nebyla dokončena.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-9bbc47b4-2d27-ece6-9817-a1e8404e5f0d"
    },
    "119": {
      "code": 119,
      "label": "Neplatná nebo ztracená nastavení",
      "known": true,
      "severity": "error",
      "description": "Regulátor nemůže použít svou konfiguraci a zastavil nabíjení.",
      "helpUrl": "https://www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_75-10_up_to_100-20/en/troubleshooting.html#UUID-8e1b962b-4faa-ff81-0da7-8c76b1d34675"
    },
    "255": {
      "code": 255,
      "label": "Údaj o chybě nedostupný",
      "known": false,
      "severity": "unknown",
      "description": "Hodnota 255 (0xFF) znamená, že údaj o chybě není k dispozici.",
      "helpUrl": "https://communityarchive.victronenergy.com/storage/attachments/extra-manufacturer-data-2022-12-14.pdf#page=3"
    }
  }
}